AMC16Z series multi-loop acquisition module is independently designed to meet the needs of the increasingly high precision power distribution management requirements of the data center. It suitable for various all-round intelligent monitoring of terminal distribution equipment.
● Monitor the full power parameters of A+B double-way three-phase AC incoming circuit
● Measurement Voltage, Current, Frequency, Active Power, Reactive Power, Power Factor and etc
● 2nd~63rd&Total Harmonic
● Current&Voltage Unbalance degree
● 1-way temperature and humidity detection
● phase-sequence detection
Instrument model |
AMC16Z-ZA |
|
Measured parameters |
Voltage, current, frequency, active power, reactive power, power factor,active power, reactive power |
|
Zero ground voltage, neutral line current, total harmonic content (THD), 2-63 harmonics, current and voltage unbalance degree, current K coefficient (KF), voltage crest coefficient (CF),telephone waveform factor (THFF), peak voltage, voltage and current sequence quantity,environmental temperature and humidity. |
||
Busbar voltage |
Rated |
220VAC |
Measurement |
±20% |
|
Overload |
Instant voltage 2times/second |
|
Current incoming circuit |
Rated |
Twice 5A |
Range |
0~6A |
|
Overload |
Duration 1.2 times, instantaneous 10 times/second |
|
Temp &humidity |
Temp range |
-40℃~+99℃ |
humidity range |
20%~90% |
|
Input frequency |
45~60Hz |
|
Measurement precision |
Inlet wire |
Voltage/current level 0.2, active power/electric energy level 0.5, reactive power/electric energy level 1 |
Temp |
±1℃ |
|
Humidity |
±5% |
|
Auxiliary power supply |
Take electric signal(≤15W) |
|
Environment |
Temp |
Working:-15℃~55℃ Storage:-25℃~70℃ |
Humidity |
Relative humidity ≤93% |
|
Altitude |
≤2500m |
|
Switch output |
2-way 3A 250VAC/3A 30VDC |
|
Switch input |
6-way dry contact |
|
Communication |
RS485/Modbus-RTU |
|
Installation method |
DIN35mm Guide rail or bottom plate mounting |
|
IP grade |
IP20 |
|
Class of pollution |
2 |
|
Safety |
Insulation |
All terminals and the insulation resistance between the conductive pieces not less than 100MΩ |
Withstand voltage |
A-way voltage and current signal, B-way voltage and current signal, switch output and other ports should meet AC2kV 1min in pairs, the switch input and other ports should meet ac0.5kv 1mim, leakage current should be less than 2mA, no breakdown or flashover |
|
Electromagnetic compatibility |
Anti static interference |
Level 4 |
Electrical fast transient pulse group |
Level 3 |
|
Anti-surge interference |
Level 4 |
|
Resistance to radiation of Radio frequency electromagnetic field |
Level 3 |
Instrument model |
AMC16Z-ZA |
||
Measured parameters |
Voltage, current, frequency, active power, reactive power, power factor,active power, reactive power |
||
Zero ground voltage, neutral line current, total harmonic content (THD), 2-63 harmonics, current and voltage unbalance degree, current K coefficient (KF), voltage crest coefficient (CF),telephone waveform factor (THFF), peak voltage, voltage and current sequence quantity,environmental temperature and humidity. |
|||
Busbar voltage |
Rated |
220VAC |
|
Measurement |
±20% |
||
Overload |
Instant voltage 2times/second |
||
Current incoming circuit |
Rated |
Twice 5A |
|
Range |
0~6A |
||
Overload |
Duration 1.2 times, instantaneous 10 times/second |
||
Temp &humidity |
Temp range |
-40℃~+99℃ |
|
humidity range |
20%~90% |
||
Input frequency |
45~60Hz |
||
Measurement precision |
Inlet wire |
Voltage/current level 0.2, active power/electric energy level 0.5, reactive power/electric energy level 1 |
|
Temp |
±1℃ |
||
Humidity |
±5% |
||
Auxiliary power supply |
Take electric signal(≤15W) |
||
Environment |
Temp |
Working:-15℃~55℃ Storage:-25℃~70℃ |
|
Humidity |
Relative humidity ≤93% |
||
Altitude |
≤2500m |
||
Switch output |
2-way 3A 250VAC/3A 30VDC |
||
Switch input |
6-way dry contact |
||
Communication |
RS485/Modbus-RTU |
||
Installation method |
DIN35mm Guide rail or bottom plate mounting |
||
IP grade |
IP20 |
||
Class of pollution |
2 |
||
Safety |
Insulation |
All terminals and the insulation resistance between the conductive pieces not less than 100MΩ |
|
Withstand voltage |
A-way voltage and current signal, B-way voltage and current signal, switch output and other ports should meet AC2kV 1min in pairs, the switch input and other ports should meet ac0.5kv 1mim, leakage current should be less than 2mA, no breakdown or flashover |
||
Electromagnetic compatibility |
Anti static interference |
Level 4 |
|
Electrical fast transient pulse group |
Level 3 |
||
Anti-surge interference |
Level 4 |
||
Resistance to radiation of Radio frequency electromagnetic field |
Level 3 |