AKH-0.66 I Current transformer

Short Description:

● Measurement: Alternating Current (AC)

● Accuracy: Class 0.2/Class 0.5/Class 1.0

 Primary Current Input: 15~3000A AC

● Application: On Busbar or Cable

● Rated Voltage: 660V AC

● Rated Frequency: 50~60Hz

● Installation: Fixed by Sheet Metal/Fixed by Clutch Cover/35mm DIN Rail

 Loop Count of Cable: 1

● Standard&Certificate: IEC/EN61869-1;IEC/EN61869-2;CE


Product Detail

Spec. and size

Size(mm) 

Type

Outline size Through size Mounting size  

Tolerance

(mm)

W

H

D

a

e

Φ

M

N

30 I

60

78

36

31

11

22

34

57.5

   

±1

40 I

75

95

45

40

11

31

40

57.5

60 I

102

130

45

61.5

21

45

42

57.5

80 I

118

140

45

82

11

52

60

57.5

1

Cross-reference tables of spec. –parameter

Specification  Rated current ratio (A)

Precision degree and corresponding rated load

(VA)

Straight- through tums  Bus spec(mm)/number

Max. cable outer diameter (mm)

 Install ation

0.2

0.5

1

   

1

 

30I

15/5(1)

   

1.5

5   

/

       

 

 

 

 

 

Ф22

  

A

20/5(1)

   

1.5

4

25-30/5(1)

   

1.5

3

40-60/5(1)

   

1.5

2

75-100/5(1)

   

1.5

1  

 

30×10/1

 

 

A、B

150-200/5(1)

 

2.5

  1

250/5(1)

 

3.75

  1

300-450/5(1)

 

5

  1

500/5(1)

 

10

  1

600/5

 

10

  1
     


 3 

 

40I

10/5(1)

   

1.5

10    

/

         

 

 

 

Ф30

 

A

15/5(1)

   

1.5

8

20/5(1)

   

1.5

5

25-30/5(1)

   

1.5

4

40/5(1)

   

1.5

3

50-75/5(1)

   

1.5

2

100/5(1)

   

1.5

1     40×10/1  

 

 

A、C

150/5(1)

   

2.5

1

200/5(1)

 

2.5

  1

250/5(1)

 

3.75

  1

300-450/5(1)

 

5

  1

500-800/5(1)

 

10

  1

1000/5(1)

10

    1
 

150/5(1)

   

2.5

1 60×10/1 Ф44 A、C
     


 4 

 

60I

200-250/5(1)

 

2.5

 

1

 

 

 

 

 

 

 

60×6/1-2

   

300-450/5(1)

 

5

 

1

500-800/5(1)

 

10

 

1

1000-1250/

5(1)

10

   

1

1500-2000/

5(1)

20

   

1

2500/5(1)

30

   

1

 2 

80I

150/5(1)

    2.5

1

    

 

 

 

80×10/1

    

 

 

 

Ф50

    

 

 

 

A、C

200-250/5(1)

 

2.5

 

1

300-400/5(1)

 

5

 

1

500-800/5(1)

 

10

 

1

1000-1250/

5(1)

10

   

1

1500-2000/

5(1)

20

   

1

2500-3000/

5(1)

30

   

1

Technical indicators

● Rated operation voltage AC 0.66kV(Equivalent AC 0.63kV,GB156-2003)

● Rated frequency 50-60Hz

● Ambient air temperature -30℃-70℃

● Height above sea level≤3000m

● Power frequency withstand voltage 3000v/1min 50Hz

● Used in place without direct rain and snow,without severe pollution and acute shock

Installation

Fixed by straight piece

1
2
3
4
5
6

Work Site Application