ADL300-EY Three-phase Prepayment Energy Meter

Short Description:

● Rated Current: 3×10(80)A AC (via direct connect); 3×1(6)A AC (via CTs)

● Rated Voltage: 3×380~456Vac L-L & 45~65Hz

● Communication: RS485 (MODBUS-RTU); Infrared

● Auto Control: Built-in Holding Relay for Switch On-off Control

● Multi-rate/tariff: 4 Tariff Rates and etc

● Standard&Certificate: CE


Product Detail

Parameter

Function

●kWh: Total active kWh (positive and negative)

●Measuring parameters: U, P,Q,S,PF,Hz,Current

●Prepaid mode Through RS485 communication prepaid recharge, data encryption

●Control: Magnetic relay

●LCD display: 8 digits

●Communication: RS485(Modbus-RTU)

Detail

1

Dimension(Unit:mm)

1

Wiring Illustration

2

Direction Connect (3-phase)

Installation Instruction

4

Work-site Installation

3

Typical Connection

4

  • Previous:
  • Next:

  • Technical Parameters

    Parameter

    Description&Value

    Measurement

    kWh&kVarh Total active kWh (bidirectional –positive and negative in total)
    Electrical Paratmeters U (Voltage), I (Current), P (Active Power), Q (Reactive Power),S (Apparent Power), PF (Power Factor), F (Frequency)

    Function Mode

    Prepaid Mode Meter will shut down the power once the credit balance is below zero. (Data like credit balance is saved in the meter)
    Postpaid Mode Meter won’t shut down the power once credit balance is below zero. (Can remotely control the meter to shut down the power by using Prepaid System)
    Mode Change Meter can change the mode between prepaid and postpaid by receiving the command from prepaid system

    Control

    Auto-tripping Control   Auto-tripping control is processed by the built-in high-capacity holding relay of the meters to realized on-off control of circuits breaker, also, this type of control will only be triggerred when meter is in Prepaid Mode
    Remote Control Remote control will be command by prepaid system. When users give a command of switch on-off to a certain meter, this command will be send to meters through wireless communication and finally meter will shut down or recover the power after receiving the command. This type of control can be done when meter is in Postpaid Mode

    Multi-rate

    Multi-Tariff

    Optional Function 4 tariff rates (spike, peak, valley, flat); 14 time intervals by day

     Input 

    Voltage

    Rated Voltage 220~264Vac L-N (Voltage signal input will be also served as power supply for meters)
    Frequency 45~65Hz

    Input

    Current

    Rated Current 10(60)A AC (via direct connect)
    Starting Current 0.004 Ib

    Accuracy

    Measurement Class 1
    Clock ≤0.5s/d

     

    Pulse

    Pulse Width 80ms±20ms
    Pulse Constant 1600imp/kWh

    Communication

    RS485 Interface MODBUS-RTU Protocol
    Infrared Used for Meter Reading

    HMI

    LCD Display 8 bits section LCD display
    Keypads Programming Setting of communication, current ratio and etc.

    Mechanical
    Feature

    Out-line Dimension
    (L*W*H)
    72mm*88mm*70mm 
    Max Wiring Ability (with Flexible Cable) 25mm2

    Environment

    Operating Temperature -25℃~+55℃
    Storage Temperature -40℃~+70℃
    Humidity ≤95% (No condensation)
    Altitude 2000m